Dell Force10 C150 Configuration Manual page 1203

Ftos configuration guide ftos 8.4.2.7 e-series terascale, c-series, s-series (s50/s25)
Hide thumbs Also See for Force10 C150:
Table of Contents

Advertisement

Note: Execute this command only during an offline diagnostics; this command may bring down the switch
fabric.
When there are a full set of SFMs online, powering down one SFM will reduce the total bandwidth
supported by the chassis, and may affect data flow. A warning message is issued at the command line that
requires user confirmation to proceed with the command
Figure 61-3. power-off sfm command with data traffic warning message
FTOS#power-off sfm 0
SFM0 is active. Powering it off it might impact the data traffic.
Proceed with power-off [confirm yes/no]:yes
Feb 15 23:52:53: %RPM1-P:CP %CHMGR-2-MINOR_SFM: Minor alarm: only eight working SFM
FTOS#
Since this command is for diagnostic purposes, you can power off more than one SFM which may cause a
switch fabric module to go down. A warning message is issued at the command line and requires user
confirmation to proceed with the command
Figure 61-4. power-off sfm command with switch fabric down warning message
FTOS#power-off sfm 1
WARNING!! SFM1 is active. Powering it off it will cause Switch Fabric to go down!!
Proceed with power-off [confirm yes/no]:yes
Feb 16 00:03:19: %RPM1-P:CP %TSM-6-SFM_SWITCHFAB_STATE: Switch Fabric: DOWN
Feb 16 00:03:20: %RPM1-P:CP %CHMGR-0-MAJOR_SFM: Major alarm: Switch fabric down
FTOS#
Once the SFM is powered off, the SFM status indicates that the SFM has been powered off by the user. Use
the show sfm all command to display the status
Figure 61-5. show sfm all command Example
FTOS#show sfm all
Switch Fabric State:
Switch Mode: SFM
--
Switch Fabric Modules
Slot
Status
---------------------------------------------------------------------------
0
power off
1
power off
2
power off
3
active
4
active
5
active
FTOS#
(Figure
(Figure
down
(Not enough working SFMs)
--
(SFM powered off by user)
(SFM powered off by user)
(SFM powered off by user)
(Figure
61-3).
61-4).
61-5).
E-Series TeraScale Debugging and Diagnostics | 1203