Recognize A Non-Recoverable Parity Error - Dell Force10 C150 Configuration Manual

Ftos configuration guide ftos 8.4.2.7 e-series terascale, c-series, s-series (s50/s25)
Hide thumbs Also See for Force10 C150:
Table of Contents

Advertisement

The line card status does not reflect transient errors until FTOS encounters five recoverable or 50 phantom
transient errors on a card within an hour, as shown in
type of parity error (transient or real) that occurred.
Use SNMP to poll the number of transient errors using the objects chSysCardParityPhantomError and
chSysCardParityRecoverableError. If it has been more than one hour since the last occurrence of the same
type of error, the counter associated with that type of error is reset to 1.
Figure 61-9. Viewing the Parity Status of a Line Card
FTOS#show linecard 6
--
Line card 6 --
Status
Next Boot
Required Type : E48TF - 48-port 10/100/1000Base-T line card with RJ-45 interfaces (EF)
Current Type
Hardware Rev
Num Ports
Up Time
FTOS Version
Jumbo Capable : yes
Boot Flash
Memory Size
Temperature
Power Status
Voltage
Serial Number : 0045149
Part Number
Vendor Id
Date Code
Country Code
Parity Status : Last Event - FPC DDR Bank [191:128], Transient Failure, Running Count 5
FTOS#show linecard 7 | find "Parity Status"
Parity Status : Last Event - FPC DDR Bank [191:128], Real Failure, Address 0x11ffe00

Recognize a non-recoverable parity error

FTOS generates a message similar to
Message 12 Console Real Parity Error Message
Apr 29 18:52:50: %RPM0-P:CP %CHMGR-2-CARD_PARITY_ERR: Linecard 6 pp 0 FPC SRAM Hard parity error:
Address 0x85000004 Index 0x80000
FTOS also generates an SNMP trap, TR_CHM_SRAM_PARITY_NONRECOVERABLE, at the same
time it generates a console message for non-recoverable parity errors. Use SNMP to poll the number of
non-recoverable errors using the objects chSysCardParityNonrecovrableError.
: online
: online
: E48TF - 48-port 10/100/1000Base-T line card with RJ-45 interfaces (EF)
: Base
- 1.1
PP0 - 1.0
: 48
: 3 min, 44 sec
: 6.5.4.1
: A: 2.3.1.3
B: 2.3.1.3 [booted]
: 268435456 bytes
: 42C
: AC
: ok
: 7520016602 Rev 06
: 04
: 01442005
: 01
Message 12
Figure
61-9. The text "Last Event" indicates the last
PP1 - 1.0
when it encounters a real transient parity error.
E-Series TeraScale Debugging and Diagnostics | 1213

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents