Sample Configuration: Uplink Failure Detection - Dell Force10 C150 Configuration Manual

Ftos configuration guide ftos 8.4.2.7 e-series terascale, c-series, s-series (s50/s25)
Hide thumbs Also See for Force10 C150:
Table of Contents

Advertisement

Sample Configuration: Uplink Failure Detection

Figure 54-7
shows a sample configuration of Uplink Failure Detection on a switch/router in which you:
Configure uplink-state group 3.
Add downstream links Gigabitethernet 0/1, 0/2, 0/5, 0/9, 0/11, and 0/12.
Configure two downstream links to be disabled if an upstream link fails.
Add upstream links Gigabitethernet 0/3 and 0/4.
Add a text description for the group.
Verify the configuration with various
Figure 54-7. Configuring Uplink Failure Detection
FTOS(conf)#
uplink-state-group 3
00:08:11: %STKUNIT0-M:CP %IFMGR-5-ASTATE_UP: Changed uplink state group Admin state to up:
Group 3
FTOS(conf-uplink-state-group-3)#
FTOS(conf-uplink-state-group-3)#
FTOS(conf-uplink-state-group-3)#
00:10:00: %STKUNIT0-M:CP %IFMGR-5-OSTATE_DN: Downstream interface set to UFD error-disabled:
Gi 0/1
FTOS#
00:10:00: %STKUNIT0-M:CP %IFMGR-5-OSTATE_DN: Changed interface state to down: Gi 0/1
FTOS(conf-uplink-state-group-3)#
FTOS(conf-uplink-state-group-3)#
!
uplink-state-group 3
description Testing UFD feature
downstream disable links 2
downstream GigabitEthernet 0/1-2,5,9,11-12
upstream GigabitEthernet 0/3-4
FTOS(conf-uplink-state-group-3)#
FTOS(conf-uplink-state-group-3)#exit
FTOS(conf)#exit
FTOS#
00:13:06: %STKUNIT0-M:CP %SYS-5-CONFIG_I: Configured from console by
FTOS#
show running-config uplink-state-group
!
uplink-state-group 3
description Testing UFD feature
downstream disable links 2
downstream GigabitEthernet 0/1-2,5,9,11-12
upstream GigabitEthernet 0/3-4
FTOS#
show uplink-state-group 3
Uplink State Group: 3
FTOS#
show uplink-state-group detail
(Up): Interface up
Uplink State Group
Upstream Interfaces
Downstream Interfaces : Gi 0/1(Dis) Gi 0/2(Dwn) Gi 0/5(Dwn) Gi 0/9(Dwn) Gi 0/11(Dwn)
show
commands.
downstream gigabitethernet 0/1-2,5,9,11-12
downstream disable links 2
upstream gigabitethernet 0/3-4
description Testing UFD feature
show config
Status: Enabled, Up
(Dwn): Interface down
: 3
Status: Enabled, Up
: Gi 0/3(Up) Gi 0/4(Dwn)
Gi 0/12(Dwn)
(Dis): Interface disabled
console