OmniAccess AP60/61: Installation Guide
The maximum length for FE cables is 100 meters (325 feet).
When the OmniAccess AP60/61 is installed in an air-handling space, as
described in NEC (2002) Article 300.22 (C), POE is required. Also, any FE cable
installed in such spaces should be suitable under NEC Article 800.50 and
marked accordingly for use in plenums and air-handling spaces with regard to
smoke propagation, such as CL2-P , CL3-P , MPP or CMP .
Install cables in accordance with all applicable local regulations and practices.

Serial Breakout Adapter

The optional serial breakout adapter is used to separate the serial
communications lines from the OmniAccess AP60/61 FE+SPOE port. This
allows the administrator to connect a local serial console directly to the AP and
access the apboot prompt for manual provisioning.
The serial breakout adapter pin-outs are shown in
36
Part 031643-00 Rev. 01
DB-9 Female Pin-Out
5
SG
9
4
8
TxD
3
7
RxD
2
6
1
RJ-45 Male "To AP" Pin-Out
1
ETH Rx+
2
ETH Rx–
3
ETH Tx+
Serial TxD
4
5
Serial TGND
6
ETH Tx–
7
Serial RxD
8
Serial RGND
RJ-45 Male "To Network" Pin-Out
1
ETH Tx+
2
ETH Tx–
3
ETH Rx+
4
5
6
ETH Rx–
7
8
F
A-2 Alcatel Serial Breakout Adapter
IGURE
Figure A-2
Internal Adapter Wiring
Direction
1 2 3 4 5 6 7 8 9
Input
Output
(POE negative)
(POE negative)
1 2 3 4 5 6 7 8
(POE positive)
"To AP"
(POE positive)
(POE negative)
(POE negative)
(POE positive)
(POE positive)
:
To Console
1 2 3 4 5 6 7 8
"To Network"
June 2005