Db-9 Specification; To Ap" Specifications; To Network" Specifications - Alcatel-Lucent OmniAccess AP60 Installation Manual

Wireless access point
Table of Contents

Advertisement

DB-9 Specification

The DB-9 connector attaches to the serial port of a console terminal.
Communication settings for the port are specified in
T
ABLE
Baud Rate
Data Bits
9600

"To AP" Specifications

The RJ-45 connector labeled "To AP" attaches to the OmniAccess AP60/61 FE
port either directly (if the AP is physically available) or indirectly (if the AP is
already deployed).
When connecting indirectly, use a straight-through FE coupler to attach the "To
AP" connector to the FE cable leading directly to the AP's FE port with no
intervening hubs, routers, or other network equipment. The cable must be
8-conductor, Category 5 UTP , straight-through FE cable with a maximum length
of 100 meters (325 feet).
The OmniAccess AP60/61 and serial breakout adapter are plenum rated.
When is installed in an air-handling space, as described in NEC (2002) Article
300.22(C), any connecting FE cable should be suitable under NEC Article
800.50 and marked accordingly for use in plenums and air-handling spaces
with regard to smoke propagation, such as CL2-P , CL3-P , MPP or CMP .
Install cables in accordance with all applicable local regulations and practices.

"To Network" Specifications

The RJ-45 connector labeled "To Network" attaches to an FE LAN segment.
This connection is optional unless IEEE 802.11af Power Over Ethernet (POE) is
used to power the AP during manual provisioning.
A straight-through FE coupler may be used to attach the "To Network"
connector to a LAN FE cable. The appropriate cable depends on the level of
connectivity required of the FE port:
If the connecting device supports IEEE 802.3af Power Over Ethernet (POE),
use a 4- or 8-conductor, Category 5 UTP , straight-through FE cable with
male RJ-45 connectors.
The OmniAccess 6000 (with Line Card OAW-LC-2G24FP), the OmniAccess
4324, the Alcatel 4304, and the OmniAccess 4308 support SPOE.
A-1 Console Terminal Settings
Parity
8
None
Table A-1
:
Stop Bits
Flow Control
1
None
Port Specifications
Appendix A
37