1 Connect the adapter's "To AP" RJ-45 connector to the Omni-
Access AP60/61 FE Port.
2 Connect the adapter's DB-9 connector to the serial port on
the console terminal.
3 Connect the adapter's "To Network" RJ-45 connector to the
LAN.
The LAN connection is optional unless POE is being used to power the AP . For
convenience, the adapter kit includes an FE coupler to connect RJ-45 cable
ends together.
4 Connect power to the OmniAccess AP60/61.
—Be sure to comply with electrical grounding standards during all phases of
C
AUTION
installation and operation of the AP. Do not allow the OmniAccess AP60/61 or optional
power adapter (if used) to be connected to or make contact with metal or power outlets on a
different electrical ground than the device to which it is connected. Also, never connect the
AP to external storm grounding sources.
The OmniAccess AP60/61 can receive electrical power using the following
options:
POE–If connecting the OmniAccess AP60/61 to a device that supplies IEEE
802.3af compliant POE, no additional power connection is necessary.
Power Outlet
N
—When the OmniAccess AP60/61 is installed in an air-handling space, as
OTE
described in NEC (2002) Article 300.22(C), POE must be used instead of a power
outlet.
If local regulations and practices permit, connect the optional AC power
adapter (not included) to the DC power socket on the rear panel of the
OmniAccess AP60/61 and plug it into an appropriate power outlet.
C
AUTION
adapter certified for this device in the country where it is used.
—The indicator LEDs on the OmniAccess AP60/61 will remain dark during this procedure.
N
OTE
—To prevent personal injury or damage to equipment, use only the AC power
Chapter 2
Provisioning Access Points
17