Facing Example - Facing Over 1" Thick - FireplaceXtrordinair 44 DV XXL EF Manual

Built-in direct vent fireplace
Hide thumbs Also See for 44 DV XXL EF:
Table of Contents

Advertisement

Facing Example – Facing Over 1" Thick
Arched Faces:
Rectangular Faces: For facing material over 1" thick (e.g. brick, river rock), install the facing material with a 1/8"
Top View
3-d View
Travis Industries
Installation
For facing material over 1" thick (e.g. brick, river rock), install the facing around the
perimeter of the set-up face shipped with the fireplace. See the illustration below.
gap to side side of the face and 3/8" gap along the top of the face (for face installation).
Use the face being installed to create a form to support the facing as it is being installed.
Fireplace
1"
1/8"
Faceplate
Non-Combustible Facing (cement board)
NOTE: a 3/8" gap is required along the top of the face for architectural faces.
Note: if using a brick hearth, the fireplace will need to be raised to accommodate the 1" gap betwen the face and the
base of the fireplace. For 2-1/2" thick brick this works out to approximately 1-1/2" (we recommend 1-5/8" to accomodate
irregular surfaces).
(for qualified installers only)
1" Stand-off
Brick
The brick facing must meet the requirements listed
under "Facing Requirements".
Set-Up Face
(shipped with the fireplace - 1/16" taller and 1/8"
wider than the finished face)
1"
4050114
Note: The brick tucks below the
face template.
1 0 0 - 0 1 1 4 9
2 7

Hide quick links: