Optional Equipment
4
Remove the pilot orifice following the instructions below. Replace with the propane pilot orifice
Lift the pilot hood
a
off the pilot
assembly.
5
Install the logs and embers.
6
Replace glass and face.
7
Remove the regulator from the front of the gas control valve. Replace with the propane regulator, using the
new gasket and screws included with the regulator. NOTE: Leak test this area after the heater is
installed, gas is connected, and the main burner is lit.
a
Remove and discard the three
screws using a slotted screwdriver
of Torx T-20.
Slotted
Screwdriver
(or T-20 Torx)
8
Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly leak-test all gas
connections and the gas control valve. Check the pilot. Adjust if necessary.
WARNING:
When lighting or re-lighting the pilot, the glass must be removed (see page
2 9 ) .
To adjust the pilot flame, turn this screw (NOTE: if totally
unscrewed gas will come out of this port). Clockwise
lowers the flame while counter-clockwise raises it.
9
Inspect the flames. Adjust the air shutter if necessary (see step 7 on page 35).
Travis Industries
Use a hex wrench to
b
unscrew the orifice.
5/32" Hex
NOTE: when re-attaching,
this pin lines up with the
notch in the pilot hood.
c
Install the LP regulator. Use
the screws included with the
LP regulator. Tighten to
approximately 25 Lbs. torque.
Slotted
b
Screwdriver
(or T-20 Torx)
Remove and discard the
regulator, diaphram, spring
and center post.
Standard
Screwdriver
4050114
(for qualified installers only)
Remove the orifice and replace with the LP orifice. Screw the
c
orifice all the way in and replace the pilot hood.
NOTE: Make sure the
regulator gasket is correctly
aligned before installation.
d
Place the LP
label on the base
of the fireplace
near the gas
control valve.
The pilot flame must contact the thermocouple and
thermopile (see the illustration below). Adjust the pilot up or
down as necessary.
Orifice Identification:
LP (Propane) Orifice
35
35
NG (Natural Gas) Orifice
62
1 0 0 - 0 1 1 4 9