Optional Equipment
8
Run the free wire from the rheostat junction box to the fireplace. Follow the directions below to connect the
heat duct circuit to the fireplace.
a
Standard
Screwdriver
MAINTENANCE INSTRUCTIONS
Once a year the grate should be removed and the blower area cleaned. Use a vacuum to clean around the
squirrel-cage blower, being careful not to damage any of the blades.

Modulating Remote Installation

Follow the directions included with the remote for installation with the exception of the receiver heat shield.
For the 44 DV EF, use the modulating remote receiver heat shield included inside the fireplace (to the left of
the gas control valve) instead of the heat shield included with the kit.
Travis Industries
Remove the cover from the
fireplace junction box.
Note: you may need to loosen this cable
clamp to ease removal of the cover plate.
b
Pry out and discard
this knock-out.
Grill
Phillips
Screwdriver
(for qualified installers only)
Insert the sheathed cable from the rheostat through a
cable clamp and push the cable clamp into the knock-out
c
hole to secure it in place. Once the wires are attached,
tighten the clamp to secure the cable.
Power
Source
for
Fireplace
Electrical Connector
(included with the
heat duct kit)
Attach the common (white), ground (exposed or green) wires, and hot
d
(black) wires from the cable leading to the rheostat to the molex
connector. Then attach the molex connector to the fireplace.
Use a vacuum cleaner to remove
any debris from the power vent
blower.
4050114
5 5
Standard
Screwdriver
e
Replace
the cover
removed
in step "a".
To optional second
power heat vent (use
the center knock-out).
1 0 0 - 0 1 1 4 9