FireplaceXtrordinair 44 Elite-ZC Installation Manual

FireplaceXtrordinair 44 Elite-ZC Installation Manual

Zero clearance fireplace

Advertisement

Quick Links

TM
• Zero Clearance
Listed
Tested to:
Fireplace
U.L. 127 and portions
of U.L. 1482 & 907
I
M
44 E
-ZC
LITE
NSTALLATION
ANUAL
10850 117th Place N.E. Kirkland, WA 98033
Part # 93508093
4020405
$10.00

Advertisement

Table of Contents
loading

Summary of Contents for FireplaceXtrordinair 44 Elite-ZC

  • Page 1 • Zero Clearance Listed Tested to: Fireplace U.L. 127 and portions of U.L. 1482 & 907 44 E LITE NSTALLATION ANUAL 10850 117th Place N.E. Kirkland, WA 98033 Part # 93508093 4020405 $10.00...
  • Page 2: Table Of Contents

    ABLE OF ONTENTS Features & Specifications Features: ..................1 Installation Options: ................1 Heating Specifications ................1 Dimensions ..................1 Installation Installation Preparation ...............2 Packing List ..................2 Fireplace Placement Requirements............3 Minimum Framing Dimensions ............3 Clearances ...................4 Corner Installation ................4 Raised Fireplaces................5 Facing Requirements .................5 Mantel Requirements .................7 Hearth Requirements .................7 Cooling Vents ...................8...
  • Page 3: Features

    EATURES AND PECIFICATIONS Features: Installation Options: • EPA Phase II approved (2.5 g/hr.) • Interior or Exterior Blower • Maximum Log Length of 32" • Straight or Corner Placement • Large firebox capacity - 4.3 cu. ft. • Flush or Recessed Face •...
  • Page 4: Installation

    NSTALLATION Installation Preparation Read this entire manual before installing the fireplace. Failure to install this fireplace in accordance with all local codes and the requirements listed in this manual may result in property damage, bodily injury, or even death. Notify your insurance company before installing this fireplace. The requirements listed below are divided into sections.
  • Page 5: Fireplace Placement Requirements

    NSTALLATION ONTINUED Fireplace Placement Requirements Minimum Framing Dimensions A firestop is required at the top of the fireplace enclosure or ceiling level (whichever is lower). The fireplace enclosure must not be Min. 4-1/2" less than 81" above the base of the fireplace.
  • Page 6: Clearances

    NSTALLATION ONTINUED • Fireplace must be installed on a level surface capable of supporting the fireplace and chimney • Place the ember strip included with the fireplace below the front edge of the fireplace. EMBER STRIP The ember strip insures no ember falls INSTRUCTIONS between the fireplace and hearth onto the...
  • Page 7: Raised Fireplaces

    NSTALLATION ONTINUED Raised Fireplaces • If the fireplace is raised more than 15” above the sub-floor, the fireplace enclosure will have to be raised accordingly (see “Minimum Framing Dimensions” on page 3). + The fireplace may be placed on a platform designed to support the fireplace and vent (Approximately 600 Lbs.).
  • Page 8 NSTALLATION ONTINUED Facing Requirements (continued) • The combustible area above the facing must not protrude more than 3/4" from the facing. If it does, it is considered a mantel and must meet the mantel requirements listed in this manual. • To achieve a facing that is flush with the drywall to the side of the fireplace, recess the framing directly next to the fireplace.
  • Page 9: Mantel Requirements

    NSTALLATION ONTINUED Mantel Requirements • The optional mantel must be a minimum 23" above the top of the faceplate (61" above the base) • The mantel must not extend more than 8-1/2" in front of the facing surface (combustible or non- combustible).
  • Page 10: Cooling Vents

    NSTALLATION ONTINUED Cooling Vents The cooling vents provide cooling air for the fireplace and chimney system. Failure to correctly install the cooling vents will lead to an extremely dangerous installation and possibly a fire. • The two cooling vents must be installed so as to route air from the outside to the two starter collars on the top rear corners of the fireplace.
  • Page 11: Blower

    NSTALLATION ONTINUED Blower The external blower pushes air through blower duct to the fireplace, where it is heated and distributed into the room. The blower may be located to draw air from the exterior of the home, producing positive pressure inside the home. Or, if desired, the blower may be located to draw air from the interior of the home.
  • Page 12: Blower Electrical Connection

    NSTALLATION ONTINUED Blower Duct Connection (continued) • The maximum length for 8" diameter blower duct is 25' (use two 6" to 8" adapters) Caulk around all Blower • A maximum of two 90° bends may be used. four sides of the Cover blower housing •...
  • Page 13: Chimney

    NSTALLATION ONTINUED Chimney Requirements • Use one of the following brands and type of chimney: • Temco 82 • Superior TF8 • FMI 8DM • Marco 8D Chimneys Part Numbers Chimney Temco 82 Superior FMI 8DM M a r c o Components T F 8 12"...
  • Page 14: Chimney Height

    NSTALLATION ONTINUED Chimney Height 2' Min. • Minimum 15' system height Rain Cap (measured from the base of the 3' Min. fireplace) Storm Collar Flashing • Maximum 35' system height (measured from the base of the Attic Firestop (with insulation shield) fireplace) ? In some Chimney must be totally...
  • Page 15: Using Offsets

    NSTALLATION ONTINUED Using Offsets • 30° Elbows may be used to offset the chimney (to align the chimney or gain clearance to combustibles • A maximum four 30° elbows may be used • Each elbow must be used in conjunction with a return elbow (so the chimney returns to a vertical direction) •...
  • Page 16: Clearances To Combustibles

    NSTALLATION ONTINUED Clearances to Combustibles Follow the clearances listed below - do not follow the clearances listed in the chimney instructions • Maintain a 2" clearance from the chimney to combustibles (measured horizontally) • Use offsets, if necessary, to maintain clearances •...
  • Page 17: Framing The Roof

    NSTALLATION ONTINUED Framing the Roof • Follow the manufacturer's instructions for the use of flashing and an adjustable storm collar at the roof line to prevent water from entering the house. • The table below may be used to determine the appropriate framing size. When installing into a sloped roof, it is important to determine the size of the framing for clearance purposes.
  • Page 18: Finalizing The Installation

    NSTALLATION ONTINUED Finalizing the Installation ACID WASH WARNING : Before installing the faceplate, make sure any masonry that has been treated with acid wash has been properly neutralized (this is used primarily with brick faces). Acid wash (muriatic acid) is used to remove excess mortar. If not properly neutralized with an ammonia solution, the gold face may develop a permanent tarnish when the acid evaporates over time.
  • Page 19 NSTALLATION ONTINUED 5 Make sure the insulation between the firebox and fireplace can is still in place Before putting on the faceplate, make sure the insulation is in place and forms a barrier between the firebox and the zero-clearance can. Check both sides and above the firebox.
  • Page 20 NSTALLATION ONTINUED 8 Attach the two male quick-connects from the switch plate to the two female quick-connects leading from the fireplace. If the optional summer fan switch is being used, connect the other two quick connects, otherwise tuck the two male quick-connects leading from the fireplace into the cavity behind the faceplate.
  • Page 21 NSTALLATION ONTINUED 10 This fireplace will accept doors originally made for the earlier fireplace, the 44A. These doors are identical except for the heat shield and glass attachment screws. The illustration below shows how to identify doors and how to switch over 44A doors to fit the 44-Elite (if necessary). 44 Elite Door 44-A Door 13-7/8”...
  • Page 22 NSTALLATION ONTINUED 11 Hang the doors on the fireplace and level them if necessary. Slide the doors into place. Check the position of the doors for horizontal Door alignment (the doors in this picture are out of alignment). Add washers (included with the doors) to the hinge pins...
  • Page 23: Listing Information

    ISTING NFORMATION The listing label can be found on the base of the fireplace behind the faceplate.
  • Page 24: Index

    NDEX 120701 Acid Wash ............16 Firestops ............14 Baffle Placement ..........16 FMI Chimney............11 Blower...............9 Framing Dimensions ..........3 Blower Duct Connection ........9 Grate Placement ..........16 Blower Electrical Connection .........10 Header (see framing dimensions) ......3 Blower Housing...........10 Hearth Requirements ...........7 BTU Output............1 Heat Shield (switching old to new style) ....19 Chimney............11 Heating Specifications ..........1 Chimney Cap (see Chimney Termination)....15...