Installation, cont'd
Figure 2-20 — RJ-45 connector and pinout tables
Reset button
10
2-16
CrossPoint 450 Plus and MAV Plus Switchers • Installation
Side
Insert
Twisted
Pair Wires
Reset button — The Reset button initiates four levels of reset to the
matrix switcher. Press and hold the button while the switcher is
running or while you power up the switcher for different reset
levels.
See "Reset button" in chapter 3, "Operation", for details.
•
Events (mode 3) reset — Hold Reset for 3 seconds then release and push
again to toggle events monitoring on and off.
•
IP settings (mode 4) reset — Hold Reset for 6 seconds then release and
push again to reset the switcher's IP functions.
IP settings reset does not replace any user-installed firmware.
•
Absolute (mode 5) reset — Hold Reset for 9 seconds then release and
push again to restore the switcher to the default factory conditions.
•
Hard reset — Hold Reset while powering up the switcher to restore the
switcher to the default factory conditions.
Hard reset does not clear the current configuration.
Patch (straight) cable
Side 1
Pin
Wire color
1
White-orange
2
Orange
RJ-45
3
White-green
connector
4
Blue
5
White-blue
6
Green
7
White-brown
8
Brown
Crossover cable
Side 1
Pin
Wire color
1
White-orange
2
Orange
3
White-green
4
Blue
5
White-blue
6
Green
7
White-brown
8
Brown
Side 2
Pin
Wire color
1
White-orange
2
Orange
3
White-green
4
Blue
5
White-blue
6
Green
7
White-brown
8
Brown
Side 2
Pin
Wire color
1
White-green
2
Green
3
White-orange
4
Blue
5
White-blue
6
Orange
7
White-brown
8
Brown