Use Daylight Savings checkbox

Click in the Use Daylight Savings checkbox. When Daylight Savings Time is
turned on, the switcher automatically updates its internal clock between Standard
Time and Daylight Savings Time in the spring and fall on the date that the time
change occurs in the country or region selected. When Daylight Savings Time is
turned off, the switcher does not adjust its time reference.

Administrator Password field

The Administrator Password field displays the password required to log on to the
CrossPoint 450 Plus or MAV Plus switcher via the Ethernet port with all of the administrator's
rights and privileges. Passwords are case sensitive and are limited to 12 upper case
and lower case alphanumeric characters.
While you are logged on as a user, this field is masked with asterisks (************)
as a security measure.
Editing the Administrator Password field while connected via the Ethernet
port can immediately disconnect the user from the switcher. Extron
recommends editing this field using a serial port and protecting the Ethernet
access to this screen by assigning an administrator's password to qualified and
knowledgeable personnel only.
The following characters are invalid in passwords: {space} + ~ , @ = ' [ ]
{ } < > ' " ; : | \ and ?.
Edit this field as follows:
1.
Click in the Administrator Password field. The graphic cursor becomes a text
cursor.
2.
Edit the case-sensitive password as desired.
3.
Press the Tab key on the keyboard or click in another field to exit the
Administrator Password field.
4.
Click the Take button to make the password change take affect.

User Password field

The User Password field displays the password required to log on to the
CrossPoint 450 Plus or MAV Plus switcher via the Ethernet port as a user, without
all of the administrator's rights and privileges. Passwords are case sensitive and
are limited to 12 upper case and lower case alphanumeric characters.
While you are logged on as a user, this field is masked with asterisks (************)
as a security measure.
An administrator password must be created before a user password can be
created.
The following characters are invalid in passwords: {space} + ~ , @ = ' [ ]
{ } < > ' " ; : | \ and ?.
Edit this field as follows:
1.
Click in the User Password field. The graphic cursor becomes a text cursor.
2.
Edit the case-sensitive password as desired.
3.
Press the Tab key on the keyboard or click in another field to exit the User
Password field.
4.
Click the Take button to make the password change take affect.