This option is enabled (check box not selected) by default. In most cases this
option should be enabled so that attached devices can receive notification of
zoning changes in the fabric. However, some HBAs may log out, then log back
into the fabric when they receive an RSCN, thereby disrupting Fibre Channel
traffic. Consult with your HBA and storage device vendor to determine if
disabling this option (and thereby enabling RSCN transmission) will cause
problems with your HBA or storage products.

Director Speed

At the Director Speed field, choose 1 Gb/sec or 2 Gb/sec to select the speed of
Fibre Channel operation.
Note:
cause the following warning/confirmation message to display: "All FPM ports
will be held inactive while the switch is configured to 2
Gb/sec speed. Do you want to continue?"

Configure Fabric Parameters

Use procedures in this section to set parameters on the director for fabric
operation through the Configure Fabric Parameters dialog box. These
parameters are stored in NV-RAM on the director.
1. Verify that the director is set offline. For instructions, see
2. Choose Configure > Operating Parameters > Fabric Parameters. The
Director 2/64 Installation Guide
Changing the switch speed to 2 Gb/s with any 1 Gb/s FPM cards installed will
Offline" on page 87.
Caution:
Setting the director offline terminates all Fibre Channel connections.
Configure Fabric Parameters dialog box displays, as shown in
Installing and Configuring the Director 2/64
"Set the Director
Figure
42.
93