Ctp2 Card; Front Bezel - HP Surestore 64 - Director Switch Installation Manual

Fw 05.01.00 and sw 07.01.00 director 2/64 installation guide (aa-rsngc-te/958-000289-001, june 2003)
Hide thumbs Also See for Surestore 64 - Director Switch:
Table of Contents

Advertisement

Overview

CTP2 Card

The Director 2/64 ships with two Control Processor (CTP2) cards. The active
CTP2 card initializes and configures the director after power on, and contains the
microprocessor and associated logic that coordinate director operation. The
second CTP2 card serves as a backup. A CTP2 card provides an Initial Machine
Load (IML) button on the faceplate. When the button is pressed and held for three
seconds, the director reloads firmware and resets the CTP2 card without switching
off power or affecting operational fiber-optic links.
Each CTP2 card also provides a 10/100 megabit per second (Mbps) RJ-45 twisted
pair connector on the faceplate that attaches to an Ethernet Local Area Network
(LAN).
Each CTP2 card provides System Services Processor (SSP) and Embedded Port
(EP) subsystems. The SSP subsystem runs director applications, communicates
with director ports, and controls the RS-232 maintenance port and 10/100 Mbps
ethernet port. The EP subsystem provides Class F processing, and manages frame
transmission to and from the Serial Crossbar Assembly (SBAR). In addition,
CTP2 cards provide non-volatile memory for storing firmware director
configuration information, persistent operating parameters, and memory dump
files. Director firmware is upgraded concurrently (without disrupting operation).
Each card faceplate contains a green light emitting diode (LED) that turns O
the card is operational and active, and an amber LED that turns O
fails. The LEDs are O
beaconing is enabled.

Front Bezel

The bezel at the front of the Director 2/64 includes two indicator LEDs. The green
power LED turns O
turns O
director power distribution failure is indicated.
The amber system error LED turns O
requiring immediate operator attention, such as an FRU failure. The LED remains
illuminated as long as an event is active. The LED F
enabled.
28
on the backup CTP2. The amber LED F
FF
when the director is powered on and operational. If the LED
N
, a facility power source, alternating current (AC) power cord, or
FF
when the director detects an event
N
LASHES
Director 2/64 Installation Guide
if
N
if the card
N
if
LASHES
if unit beaconing is

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks director 2/64

Table of Contents