Manage Firmware Versions
Figure 61: Backup and Restore Configuration dialog box
5. Choose Maintenance > Firmware Library. The Director Firmware
6. Choose the firmware version to be downloaded and click Send. The send
Figure 62: Send Firmware confirmation box
7. Click Yes. The Send Firmware dialog box displays.
124
c. Choose Maintenance > Backup & Restore Configuration. The Backup
and Restore Configuration dialog box displays, as shown in
d. Click Backup. When the backup process finishes, the Backup Complete
dialog box displays.
e. Click OK to close the dialog box and return to the Hardware View page.
Library dialog box displays, as shown in
function verifies existence of certain director conditions before the download
process begins. If an error occurs, a message displays indicating the problem
must be fixed before firmware is downloaded. Conditions that terminate the
process include:
A redundant CTP2 card failure.
The firmware version is being installed to the director by another user.
The director-to-HAFM server link is down.
If a problem occurs and a corresponding message displays, refer to the HP
StorageWorks Director 2/64 Service Manual for specific information on
isolating the problem. If no error occurs, the Send Firmware confirmation
box displays, as shown in
As the download begins, a "Writing data to FLASH" message
displays at the top of the dialog box, followed by a "Sending Files"
message. This message remains as a progress bar travels across the dialog box
Figure
Figure
62.
Figure
57.
Director 2/64 Installation Guide
61.