Install Mounting Bracket Hardware In The Rack; Securing The Rear Angle Brackets - HP Surestore 64 - Director Switch Installation Manual

Fw 05.01.00 and sw 07.01.00 director 2/64 installation guide (aa-rsngc-te/958-000289-001, june 2003)
Hide thumbs Also See for Surestore 64 - Director Switch:
Table of Contents

Advertisement

Installing and Configuring the Director 2/64
3. Lower the rack feet (2) until they touch the floor.
Figure 15: Mounting anti-tip feet for a HP system/e rack

Install Mounting Bracket Hardware in the Rack

Use these steps to install the mounting hardware in a rack.
Note:
the 9Us. Note also that 1U below the switch is required for the rail tray for a total of
10U to mount the switch.
1. Determine the appropriate placement for the switch inside the rack. It is
2. Determine the mounting location for the rail tray, as shown in
Note:
mounted no higher than U11, the tray should be mounted no higher than U10. Make
sure there are at least 2Us above the top of the switch empty for the sliding shelf.
3. Locate the rail tray and two rail tray brackets in the shipping carton.
58
The 9Us used to mount the switch are called U1 through U9; U1 is the lowest of
important to consider the number of switches you intend to install. See
for Installing More than One
The rail tray will be mounted 1U below the switch. Because the switch should be
Switch" on page 49.
Figure
16.
Director 2/64 Installation Guide
"Tips