5050-001
Installation Note: When you connect the terminals be sure to
connect them to the correct position. Also, after the terminals are
connected, firmly insert the insulating cover.

Power Supply Board (P614-MPS) Removal

1. Remove the rear cover, the front cover, and the left side cover.
2. Remove the connectors on the board.
3. Remove the ground wire
(green/yellow, gray, 117 V only / 1 screw).
4. Remove the I/R lever: B, (S-tight 3x6 / 2 screws).
5. Remove the shield plate, (S-tight 3x6 / 8 screws).
6. Remove the insulating sheet and power supply board,
(S-tight 3x6 / 5 screws).
7. Remove the connector of the main switch cable.
Note: Be sure the I/R lever works correctly after you reassemble.