Repair Information; Precautions For Disassembly And Cleaning; Handling The Printed Circuit Boards With Mos Ics - Lexmark Optra Color 1200 Service Manual

Service manual
Hide thumbs Also See for Optra Color 1200:
Table of Contents

Advertisement

5050-001

4. Repair Information

Precautions for Disassembly and Cleaning

Observe the following precautions whenever you service the printer:
Be sure to unplug the printer from the outlet before attempting
to service the printer.
To reassemble the printer, reverse the order of disassembly
unless otherwise specified.
Do not operate the printer anytime during disassembly. If it is
absolutely necessary to run the printer with its covers removed,
use care not to allow your clothing to be caught in revolving
parts such as the gears, rollers and fan motor.
Never touch the terminals of electrical parts or high-voltage
parts such as the high voltage unit.
Be sure to handle the fuser carefully as it remains hot for a while
after the printer stops running. Always unplug connectors by
holding the connector housing.
Be sure to use the fuse listed in the parts catalog.
Do not forget to install the ground wire or ground plate to ensure
positive conduction. Install the screw with a toothed washer in
the right position at reassembly.

Handling the Printed Circuit Boards with MOS ICs

The following precautions must be observed when handling circuit
boards with MOS (Metal Oxide Semiconductor) ICs.
During Transportation/Storage:
During transportation or when in storage, new circuit boards
must not be indiscriminately removed from their protective
conductive bags.
Do not store or place circuit boards in a location exposed to
direct sunlight.
When it becomes absolutely necessary to remove a board from
its conductive bag or case, always place it on its conductive mat
in an area as free as possible from static electricity.
Do not touch pins of the ICs with your bare hands.
Repair Information
4-1

Advertisement

Table of Contents
loading

Table of Contents