10. Installation Position of the Scanner Drive Assembly
Loosen the four screws of the scanner drive assembly; then, while pushing the scanner drive
assembly against the rear plate (direction of arrow [1]), move it in the direction of the manual feed
tray (direction of arrow [2]) so that it touches the pulley base and the lens gear. In this condition,
tighten the screws, and confirm that there is play between the lens gear and the gear of the lens drive
capstan.
11. Installing the Corona Wires in the Primary and Transfer Corona Assemblies
• The corona wire must not be bent or twisted, and the gold plating must not be peeling off.
• The corona wire must not be slack. (The length of the corona wire tension spring should be
about 12 mm.)
• The corona wire must be in the V groove of the height adjusting piece.
COPYRIGHT © 1999 CANON INC.
Pulley base
[1]
[2]
Figure 10-216
Primary corona assembly
(about 2 mm)
Trasnfer corona assembly
(about 5 mm)
Figure 10-217
CANON NP6317 REV.0 APR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 10 TROUBLESHOOTING
Pulley gear
Lens base
Lens gear
Shaft
Scanner drive
assembly
10-13