EPSON Stylus Photo R200/R210
Occurrence Timing
Phenomenon Detail
Position of CR
"PF Motor" and "Spur Gear, 37.242"
rotate properly, but "Holder, Shaft, LD
Roller" does not feed paper. (The drive
of "PF Motor" does not propagate to
"Holder, Shaft, LD Roller".)
At operation
-
"Holder, Shaft, LD Roller" is not set in
the ASF home position and paper is
always fed from "ASF Assy.".
"Holder, Shaft, LD Roller" does not feed
paper during the feeding operation. "PF
Motor" and "Spur Gear, 37.242" also
does not rotate at all.
At operation
"Holder, Shaft, LD Roller" rotates
-
properly, but paper is not fed.
TROUBLESHOOTING
Table 1-6. Check Points for Paper Out Error to Each Phenomenon
Faulty Part/
Part Name
1. Check if "Compression Spring, 2.36" of "Lever, Change"
does not come off.
Ink System
Compression Spring, 2.36
1. Check if the tip of "Lever, Change" is not damaged.
Ink System
1. Check if "PF Connector Cable" is connected to CN6 on
"Main Board".
PF Motor*
2. Check if the coil resistance of "PF Motor" is
approximately 3.0W with a tester. Refer to Table 1-1.
3. Check if "PF Motor Connector Cable" is damaged.
1. Check if the surface of "LD Roller" is contaminated with
paper dust.
Holder, Shaft
LD Roller
Unit Level Troubleshooting
Check Point
1. Replace "Ink System" with a new one.
Lever, Change
1. Replace "Ink System" with a new one.
1. Connect "PF Motor Connector Cable" to CN6
on "Main Board".
2. Replace "PF Motor" with a new one.
3. Replace "PF Motor" with a new one.
1. Remove the dust by using a soft bruch or soft
cloth moistened with alcohol.
* If the problem is not solved, replace "LD
LD Roller
Revision A
Remedy
Roller" with a new one.