Snmp Notification Filters - Dell PowerConnect 5548P System User's Manual

Dell - powerconnect switch
Hide thumbs Also See for PowerConnect 5548P:
Table of Contents

Advertisement

FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance Projects\Dell
Group Name — Select the group to be associated with the
community.
Configuring Communities Using CLI Commands
The following table summarizes the CLI commands for setting fields in the
Community pages.
Table 9-60. SNMP Community CLI Commands
CLI Command
snmp-server community community
[view view-name] [ro|rw|su]
{ipv4-address|ipv6-address}
[mask mask-value|prefix-length
prefix-value] [type router|oob]
snmp-server community-group
community group-name [ipv4-
address|ipv6-
address][mask|prefix-length]
[type router|oob]
no snmp-server community string
[ipv4-address|ipv6-address]
show snmp
The following is an example of the CLI commands:
console (config)# snmp-server community dell ro 10.1.1.1

SNMP Notification Filters

Notification filters determine the type of SNMP notifications that are sent to
the management station, based on the OID of the notification to be sent.
Each OID is linked to a device feature or a feature aspect.
SNMP notification filters provide the following services:
Identification of management trap targets
Trap filtering
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 1 / 1 2 - F O R P R O O F O N LY
330
Dell PowerConnect 55xx Systems User Guide
Contax\CxUGSystemConfig.fm
Description
Sets up the community access string
to permit access to the SNMP
protocol.
Use the no form of this command to
remove the specified community
string
Sets up community access string to
permit limited access to the SNMP
protocol, based on group access
rights.
Displays the current SNMP device
configuration.

Advertisement

Table of Contents
loading

Table of Contents