To view the results of optical fiber tests:
Click System > Diagnostics > Optical Transceiver Diagnostics in the
tree view to display the Optical Transceiver Diagnostics page.
Figure 9-30. Optical Transceiver Diagnostics
The following fields are displayed for the selected unit:
Port — The port number on which the cable was tested.
Temperature — The temperature (C) at which the cable is operating.
Voltage — The voltage at which the cable is operating.
Current — The current at which the cable is operating.
Output Power — The rate at which output power is transmitted.
Input Power — The rate at which input power is transmitted.
Transmitter Fault — A fault occurred during transmission.
Loss of Signal — A signal loss occurred in the cable.
Data Ready — The transceiver has achieved power up, and data is
ready.