Power Cords; Dc04 San Director Power Specifications - HP A7533A - Brocade 4Gb SAN Switch Base Hardware Reference Manual

Hp storageworks dc and dc04 san backbone director switches hardware reference guide (5697-7814, february 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

The power specifications in Table 20 are calculated for fully loaded systems with two power supplies,
four FC8-48 port blades, two CP8 blades, two CR4S-8 blades, and two blower assemblies.
Table 48 DC04 SAN Director power specifications
Specification
Input voltage
Input frequency range
Power supply output (each)
AC inrush current
System power consumption

Power cords

The types of power cords provided with the DC SAN Director and DC04 SAN Director are specific
to the country where it is installed. For each of these types of power cords (see
that connects to the Director chassis has an IEC 60320/C19 cable connector. The two AC power
receptacles on each chassis are equipped with IEC 60320/C20 power connectors.
Contact HP to order a power cord.
CAUTION:
Never use the power cord supplied with your DC SAN Director or DC04 SAN Director for other
products.
Table 49 Power cords
Country
Argentina
Australia
Austria
216
Technical specifications
Value
Range: 85 - 264 VAC Auto-volt, Nominal: 100 to 240 VAC
47-63 Hz; Nominal: 50 - 60 Hz
Low line (85- 132 VAC), 1000W; High line (180 - 264 VAC), 2000W
20A maximum, peak
AC power consumption is configuration-specific. A system with four
FC8-48 port blades (loaded with 1W SFPs), two CP8 blades, two
CR4S-8 blades, and two blower assemblies consumes 841W.
Plug style
NEMA L6-20
CEE-7/7
USA, Canada,
"Schuko"
Mexico, other
Continental
North Americ-
Europe/Ire-
an locations
land
X
Table
BS-1363A
AS 3112
United King-
Aus-
dom/ Hong
tralia/New
Kong
Zealand
X
49), the end
IEC-60309
32A-6h, 230
V~
X