7.
Logged into the active CP, use the configUpload command to upload the DC04 SAN Director
configuration to a specified FTP server. Enter information at the prompts.
This is a sample of backing up the configuration files:
swDir:admin> configUpload
Protocol (scp or ftp) [ftp]: ftp
Server Name or IP Address [host]: 123.456.78.90
User Name [None]: user
File Name [config.txt]: config.txt
Password: xxxxxxxx
upload complete
Removing a control processor blade (CP8)
The DC04 SAN Director continues to operate while a CP blade is being replaced if the redundant
CP blade is active and a failover does not occur. You can prevent failover by entering the haDisable
command.
CAUTION:
Wear a grounded ESD strap when handling DC04 SAN Director components. The DC04 SAN Director
chassis provides a grounding connection above the power connectors. Also, store ESD-sensitive
components in antistatic packaging.
To remove a CP blade:
IMPORTANT:
The CP8 blade is compatible with the DC SAN Director and DC04 SAN Director only.
1.
Remove the chassis door. See
2.
Login to the active CP as admin. You can use a serial cable or Telnet, Web Tools, or Fabric
Manger. Determine which CP is active using the haShow command or view the active LED on
the front of the CP.
3.
If the faulty CP is the active CP, issue the haFailover command. Wait until the failover has
completed. Use the haShow command to verify that the CPs are synchronized and the failover
is complete.
4.
Power off the blade by sliding the slider switch in the top ejector down to the off position (see
Figure
67).
5.
Disconnect all cables from the faulty (standby) CP.
6.
Unscrew the thumb screw from both ejectors using the Phillips screwdriver.
178
Replacing DC04 SAN Director field-replaceable units (FRUs)
"Removing the chassis
door" on page 169.