Turn the core switch blade on by sliding the ON/OFF switch in the top handle up, to cover the
thumb screw.
5.
Verify that the power LED is green (this may require a few seconds). If not, ensure that the core
switch blade has power and is firmly seated and that the ejectors are in the locked position.
6.
Connect to the new core switch blade.
7.
Pack the faulty core switch blade in the packaging provided with the new core switch blade,
and contact the DC04 SAN Director supplier for the procedure for returning the faulty blade.
8.
Replace the chassis door. See

Replacing a power supply

The DC SAN Director can continue operating during the replacement if at least one power supply
continues operating. The replacement procedure for each power supply takes less than five minutes.
A power supply unit or filler panel is required for the power supply replacement.

Removing a power supply

To remove a power supply:
CAUTION:
Wear a grounded ESD strap when handling DC SAN Director components. The Director chassis
provides a grounding connection above the power connectors. Also, store ESD-sensitive components
in antistatic packaging.
1.
If the DC SAN Director is not operating during the replacement procedure, go to step 2.
If the DC SAN Director is going to continue operating during the replacement, check the power
LEDs to verify that the minimum number of power supplies is functioning. A fully populated DC
SAN Director requires a minimum of one power supply slot at all times to ensure power to the
DC SAN Director.
2.
Loosen the thumb screw.
3.
Pull the handle out and down (see
4.
Support the power supply from beneath. Use the handle to remove the power supply out of the
chassis.
5.
If you are not replacing the power supply, insert a filler panel into the slot.

Installing a power supply

To install a power supply:
1.
Remove any filler panel.
2.
Insert the power supply into the slot and push the handle up. Verify that the power supply is
seated by gently pulling on the handle (see
3.
Tighten the thumb screw.
88
Replacing DC SAN Director field-replaceable units (FRUs)
"Installing the chassis
door" on page 74.
Figure
32).
Figure
32).