4.
Verify that all the IP address information is correct by typing ipaddrshow and checking the results
against the IP information recorded in the config-miscinfo.txt file.
rsl8-st03-dcx-1:admin> ipaddrshow
SWITCH
Ethernet IP Address: 10.32.50.12
Ethernet Subnetmask: 255.55.0.0
Fibre Channel IP Address: 1.2.3.4
Fibre Channel Subnetmask: 255.255.255.0
CP0
Ethernet IP Address: 10.32.50.10
Ethernet Subnetmask: 255.55.0.0
HostName : cp0
Gateway Address: 10.32.40.1
CP1
Ethernet IP Address: 10.32.50.11
Ethernet Subnetmask: 255.55.0.0
HostName : cp1
Gateway Address: 10.32.40.1
Backplane IP address of CP0 : 10.0.0.5
Backplane IP address of CP1 : 10.0.0.6
rsl8-st03-dcx-1:admin>rsl8-st03-dcx-1:admin>
Reconnecting to the network and the fabric
See the cable routing information that was recorded in
1.
Connect the CP blades to the local area network:
a.
Insert the appropriate Ethernet cables into each Ethernet port.
b.
Connect the other ends to an Ethernet 10/100 Base-T LAN, if not already connected.
IMPORTANT:
The DC04 SAN Director can be accessed by remote connection using any of the
available management tools, such as Telnet or Web Tools. Ensure that the DC04 SAN
Director is not modified using other connections during the rest of this procedure.
HP StorageWorks DC and DC04 SAN Backbone Director Switches
Table 40
on page 206 for the following steps:
203