1.
Log in to the DC04 SAN Director as admin:
rsl8-st03-dcx-1:admin> login
login: admin
password: xxxxxxxx
rsl8-st03-dcx-1:admin>
2.
Type slotShow command and verify that all the installed cards are detected and that their status
is operational (enabled).
rsl8-st03-dcx-1:admin> slotShow
Slot
Blade Type
---------------------------------
1
UNKNOWN
2
SW BLADE
3
CORE BLADE
4
CP BLADE
5
CP BLADE
6
CORE BLADE
7
UNKNOWN
8
SW BLADE
rsl8-st03-dcx-1:admin>
3.
Verify that the DC04 SAN Director is functioning correctly by typing switchShow or
switchStatusShow.
This switchShow command displays DC04 SAN Director and port status information.
rsl8-st03-dcx-1:admin> switchshow
switchName:
switchType:
switchState:
switchMode:
switchRole:
switchDomain:
switchId:
switchWwn:
zoning:
switchBeacon:
blade3 Beacon:
blade5 Beacon:
blade8 Beacon:
blade10Beacon:
Index
Slot
PortAddressMediaSpeedStateProto
===========================================================
32
3
00b2000idN4OnlineL-Port 5 public
33
3
10b2100__N8No_Module
34
3
20b2200__N8No_Module
35
3
30b2300__N8No_Module
36
3
40b2400idN4OnlineF-Port
10:00:00:00:c9:51:00:2d
37
3
50b2500__N8No_Module
rsl8-st03-dcx-1:admin>
202
Replacing DC04 SAN Director field-replaceable units (FRUs)
ID
Status
VACANT
55
ENABLED
52
ENABLED
50
ENABLED
50
ENABLED
52
ENABLED
VACANT
55
ENABLED
rsl8-st03-dcx-1
62.1
Online
Native
Subordinate
11
fffc0b
10:00:00:05:1e:39:59:67
OFF
OFF
OFF
OFF
OFF
OFF