McDATA SNMP Support
2
FcFxPortHoldTime
FcFxPortBaudRate
FcFxPortMedium
E/OS SNMP Support Manual
2-72
MicroSeconds
Type
PCP
Provided By
R
Access
The maximum time (in microseconds) that the Fx_Port shall hold a
Description
frame before discarding the frame if it is unable to deliver the frame.
The value 0 means that the Fx_Port does not support this parameter.
This is equal to quarter of d the E_D_TOV which is obtained from
PCP.
Fc0BaudRate
Type
FPM
Provided By
R
Access
The FC-0 baud rate of the Fx_Port.
Description
One of these values, or no value will be returned.
0x10,
0x20,
0x40
Fc0Medium
Type
FPM
Provided By
R
Access
The FC-0 medium of the Fx_Port.
Description
The value is a bitwise OR of these values:
0x02
0x04
0x08
Or it will be unknown (0x01) if no information is available.
1 Gbaud (100 MB/s)
2 Gbaud (200 MB/s)
4 Gbaud (400 MB/s)
Single Mode fibre
Multi-mode fibre 50 micron
Multi-mode fibre 62.5 micron