Fabric Element Management MIB
D
fcFxPortPhysLastChange
fcFxPortPhysRttov
E/OS SNMP Support Manual
D-24
mandatory
Status
The current operational status of the FxPort. The testing(3) indicates
Description
that no operational frames can be passed. If
fcFxPortPhysAdminStatus is offline(2) then fcFxPortPhysOperStatus
should be offline(2). If fcFxPortPhysAdminStatus is changed to
online(1) then fcFxPortPhysOperStatus should change to online(1) if
the FxPort is ready to accept Fabric Login request from the attached
NxPort; it should proceed and remain in the link-failure(4) state if
and only if there is a fault that prevents it from going to the online(1)
state.
Sequence
::= { fcFxPortPhysEntry 4 }
TimeTicks
Syntax
read-only
Access
mandatory
Status
The value of sysUpTime at the time the FxPort entered its current
Description
operational status. A value of zero indicates that the FxPort's
operational status has not changed since the agent last restarted.
Sequence
::= { fcFxPortPhysEntry 5 }
MilliSeconds
Syntax
read-only -- instead of read-write
Access
mandatory
Status
The Receiver_Transmitter_Timeout value of the FxPort. This is used
Description
by the receiver logic to detect Loss of Synchronization.
Sequence
::= { fcFxPortPhysEntry 6 }