Sequence
connUnitPortPhysicalNumber
Syntax
Access
Status
Description
Sequence
connUnitPortStatObject
Syntax
Access
Status
Description
Sequence
connUnitPortProtocolCap
Syntax
Access
Status
Description
::= { connUnitPortEntry 17 }
INTEGER
read-only
mandatory
This is the internal port number this port is known by. In many
implementations, this should be the same as connUnitPortIndex.
Some implementations may have an internal port representation not
compatible with the rules for table indices. In that case, provide the
internal representation of this port in this object. This value may also
be used in the connUnitLinkPortNumberX or
connUnitLinkPortNumberY objects of the connUnitLinkTable.
::= { connUnitPortEntry 18 }
OBJECT IDENTIFIER
read-only
deprecated
This contains the OID of the first object of the table that contains the
statistics for this particular port. If this has a value of zero, then there
are no statistics available for this port. The port type information will
help identify the statistics objects that will be found in the table.
::= { connUnitPortEntry 19 }
OCTET STRING (SIZE (2))
read-only
mandatory
Bit mask that specifies the driver level protocol capability of this port.
If this is not applicable, return all bits set to zero.
The bits have the following definition:
unknown - 0
FC Management MIB