McDATA 316095-B21 - StorageWorks Edge Switch 2/24 Manual page 275

Fw 08.01.00 mcdata e/os snmp support manual (620-000131-630, november 2005)
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Description
Sequence
connUnitPortStatus
Syntax
Access
Status
Description
Sequence
connUnitPortTransmitterType
Syntax
The user selected state of the port hardware.
::= { connUnitPortEntry 6 }
INTEGER {
unknown (1),
unused (2),
device cannot report this status
ready (3),
FCAL Loop or FCPH Link reset protocol
initialization has completed
warning (4),
do not use (4/12/00)
failure (5),
do not use (4/12/00)
notparticipating (6), loop notparticipating and does not have a loop
address
initializing (7),
protocol is proceeding
bypass (8),
do not use (4/12/00)
ols (9)
FCP offline status }
read-only
mandatory
An overall protocol status for the port. This value of
connUnitPortState is not online, then this is reported Unknown.
::= { connUnitPortEntry 7 }
INTEGER {
unknown(1),
other(2),
unused(3),
shortwave(4),
longwave(5),
copper(6),
scsi(7),
FC Management MIB