McDATA 316095-B21 - StorageWorks Edge Switch 2/24 Manual page 126

Fw 08.01.00 mcdata e/os snmp support manual (620-000131-630, november 2005)
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

McDATA SNMP Support
2
FcConnUnitInfo
Product Mapping
FcConnUnitControl
Product Mapping
E/OS SNMP Support Manual
2-104
SnmpAdminString
Type
A textual description of the product.
Writable and persistent across IPL.
R/W
Access
Information about this connectivity unit. This object value should be
Description
persistent between boots.
INTEGER
Type
Always return unknown (1) on read operation.
ResetConnUnitWarmStart (4), offlineConnUnit (5), and
onlineConnUnit (6) will be supported by PCP.
ResetConnUnitWarmStart (4) indicates IPL on the switch is
performed. ResetConnUnitColdStart (3) is not supported.
R/W
Access
This object is used to control the addressed connectivity unit.
Description
NOTE: 'ColdStart' and 'WarmStart' are as defined in mib-2 and are not
meant to be a factory reset.
ResetConnUnitColdStart
ResetConnUnitWarmStart The addressed unit performs a
OfflineConnUnit
OnlineConnUnit
The addressed unit performs a
'ColdStart' reset.
'WarmStart' reset.
The addressed unit puts itself into an
implementation dependent 'offline' state.
In general, if a unit is in an offline state, it
cannot be used to perform meaningful
Fibre Channel work.
The addressed unit puts itself into an
implementation dependent 'online' state.
In general, if a unit is in an online state, it
is capable of performing meaningful
Fibre Channel work.

Advertisement