McDATA 316095-B21 - StorageWorks Edge Switch 2/24 Manual page 29

Fw 08.01.00 mcdata e/os snmp support manual (620-000131-630, november 2005)
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Binding
OID
1
1.3.6.1.4.1.289.2.1.1.2.4.1.1.4.port_number+1
fcEosPortAttachedWWN.port_number+1
Enterprise-specific
Threshold Alert Trap
Binding
OID
1
1.3.6.1.4.1.289.2.1.1.2.3.1.1.1.port_number+1
fcEosPortIndex.port_number+1
2
1.3.6.1.4.1.289.2.1.1.2.6.1.1.1.threshold_number
fcEosTAIndex.threshold_number
Enterprise-specific
FRU Traps
Binding
OID
1
1.3.6.1.4.1.289.2.1.1.2.2.1.1.1.fru_code.fru_position
fcEosFruCode.fru_code.fru_position
2
1.3.6.1.4.1.289.2.1.1.2.2.1.1.2.fru_code.fru_position
fcEosFruPosition.fru_code.fru_position
3
1.3.6.1.4.1.289.2.1.1.2.1.15.0
fcEosSysSwitchName
4
1.3.6.1.4.1.289.2.1.1.2.1.16.0
fcEosSysSwitchId
This trap is sent when port traffic exceeds a specified threshold.
There are 2 variable bindings.
The enterprise specific FRU traps (FRU removed, FRU active, FRU
backup, FRU update, FRU failed: type codes 5-9) share the same
bindings. There are 4 variable bindings for these traps:
McDATA SNMP Support
Value
WWN of invalid attached device. See
definition for fcEosPortAttachedWWN.
Value
Port number of port with threshold alert.
The index of the threshold which was
triggered.
Value
The FRU code for this FRU. See table
below.
The FRU position for this FRU. The first
position is 1.
The ASCII name of the switch
The Worldwide Name of the switch.
E/OS Trap Overview