Memory initialization errors

The following table describes the memory initialization errors that can occur during
boot.
Table 11. Memory initialization errors
Code
Message
E1006
Memory Incomplete.
E1100
System memory init failure. Boot
abort.
E1110
System memory test failure. Boot
abort.
E1200
System memory init failure during
second-pass calibration. CPU
halted.
E1210
Memory controller failed. CPU
halted.
W1250 Timing Calibration failed: BE...
YRAC... DQ... pin...
Note: <xx...> indicates the
number of the pin where the error
has occurred.

USB errors

The following table describes boot list errors. These may occur when booting from a
bootable CD or DVD.
Description
Not all the XDR system memory
could be initialized.
The system XDR memory could
not be initialized. The boot process
has aborted.
An error has occurred while testing
the XDR memory.
Since the first-pass calibration
succeeded, either the CPU or the
system XDR memory could have a
defective contact.
The built-in memory controller of
the CPU encountered an
unexpected error.
This warning message
accompanies a later memory
initialization error message and
lists the pin number for help in
locating the cause of the error.
Action
The blade server can still boot but
with reduced system memory.
Power down then reboot the
blade.
If this does not resolve the
problem, contact your IBM service
representative as the system
board may need replacing.
Power down then reboot the
blade.
If this does not resolve the
problem, contact your IBM service
representative as the system
board may need replacing.
Power down then reboot the
blade.
If this does not resolve the
problem, contact your IBM service
representative as the system
board may need replacing.
Power down then reboot the
blade.
If this does not resolve the
problem, contact your IBM service
representative as the system
board may need replacing.
Power down then reboot the
blade.
If this does not resolve the
problem, contact your IBM service
representative as the system
board may need replacing.
See the accompanying memory
initialization error message for
further information.
Chapter 5. Diagnostics and troubleshooting