Table 20. BMC firmware messages (continued)
Event
Cell/B.E. processor 0 Temp
above Shut-Off Temperature (
95°C)
Cell/B.E. processor 1 Temp
above Shut-Off Temperature (
95°C)
Temp above Shut-Off
Temperature (100°C)
Cell/B.E. companion chip 2
Temp above Shut-Off
Temperature (100°C)
Cell/B.E. Events
Processor Failure Cell/B.E.
processor 0 (Checkstop)
Processor Failure Cell/B.E.
processor 1 (Checkstop)
Failure Initializing Cell/B.E.
processor 0 or Cell/B.E.
companion chip 0
Failure Initializing Cell/B.E.
processor 1 or Cell/B.E.
companion chip 1
Severity
Message
Error
Processor 1 (BE0
Temp) critical fault.
Error
Processor 2 (BE1
Temp) critical fault.
Error
Processor 3 (SB1
Temp) critical fault.
Error
Processor 4 (SB2
Temp) critical fault.
Error
CPU 1 internal fault Reboot
Error
CPU 2 internal fault Reboot
CPU 1 Fault + "Init
Error
Failed #x", where x
is a number
representing the
error condition
Error
CPU 2 Fault
Automatic Action by
BMC
Power Off
The temperature of the
processor has reached a
critical level.
Power Off
The temperature of the
processor has reached a
critical level.
Power Off
The temperature of the
system board has reached
a critical level.
Power Off
The temperature of the
system board has reached
a critical level.
Power Off
Power Off
Chapter 5. Diagnostics and troubleshooting
Action required by
user
v Check that the
BladeCenter unit
cooling system is
operating correctly.
v Replace any
missing filler
blades in the
BladeCenter unit.
v Replace any
missing filler
blades in the
BladeCenter QS21
DIMM module
sockets.
v Check that other
blade servers are
operating within the
recommended
temperature range.
v Remove and
replace the blade
server, power on
and boot.
If problem persists,
please contact IBM
service.
There may be a
problem with the
system board. If
problem persists,
please contact IBM
service.
There may be a
problem with the
system board. If
problem persists,
please contact IBM
service.
Reboot. If the
problem persists, the
blade needs to be
replaced.
91