Table 19. Other error messages (continued)
Code
Message
E1003
Firmware image incomplete
E1004
Unspecified Internal Firmware
Error
BMC firmware messages
The following is a description of the BMC firmware messages that are sent to the
Advanced Management Module. Use the Advanced Management Module Web
interface to view them.
No codes are associated with these messages. However, the status column
indicates their severity.
There are three levels of severity:
Information
Warning
Error
Description
The firmware detected missing
components and cannot continue
execution.
The firmware encountered an
unexpected error condition.
Informational messages only. No action need be taken, but you should
continue to monitor the item concerned.
A potentially serious error has occurred. The BMC has taken the action
described in the Automatic action column on the Advanced Management
Module but you may be required to take further action. See the appropriate
sections of this chapter indicated in Table 20 on page 90 for further
information
A serious error has occurred. The blade server may have been powered off
or rebooted. See the specific error for what action is required.
Action
The boot watchdog automatically
boots the system from the
permanent flash side. The
malfunctioning firmware image
should be rejected as described in
"Recovering the TEMP image from
the PERM image" on page 59.
Power down then reboot the
blade. If the problem persists,
contact your IBM service
representative as the system
board assembly may need
replacement.
The boot watchdog automatically
boots the system from the
permanent flash side. The
malfunctioning firmware image
should be rejected as described in
"Recovering the TEMP image from
the PERM image" on page 59.
Power down then reboot the
blade. If the problem persists,
contact your IBM service
representative as the system
board assembly may need
replacement.
Chapter 5. Diagnostics and troubleshooting