Table 9. System firmware boot list errors (continued)
Code
Message
E3403
Bad executable: <details>
E3404
Not a bootable device!
E3405
No such device
E3406
Client application returned an
error: <details>
E3407
Load failed
E3408
Failed to claim memory for the
executable
E3409
Unknown FORTH Word
E3410
Boot list successfully read from
VPD but no useful information
received.
Description
The file loaded from the boot
device is not a valid PPC
executable ELF file. The <details>
string provides more details about
the file type.
The system cannot load an
executable file from this device.
The specified boot device is
currently not present or not ready
for access.
The OS or a standalone
application returned an error code
to the system firmware. The
<details> string provides the error
description
Load or boot failed to load
requested file from the device.
This is informational message and
may be preceded by one or more
other error messages.
An attempt to load executable file
from the boot device failed due to
insufficient memory or firmware
problem.
Internal code error, or compatibility
issue.
The firmware found a valid VPD
but was not able to find bootable
code on any of the devices listed
in it.
Action
Using the Advanced Management
Module correct the boot device
configuration. Select a valid boot
device and executable path
Using the Advanced Management
Module correct the boot device
configuration. Select a valid boot
device and executable path.
Check the hardware device or use
the Advanced Management
Module to correct the system
configuration.
If the problem persists, contact
your IBM service representative.
Based on the <details> string you
may have to take an action on
faulty hardware or use the
Advanced Management Module to
correct the system configuration. It
may be needed to perform the
firmware or OS upgrade to resolve
compatibility issues. If the problem
persists, contact your IBM service
representative.
Based on the preceding error
messages you may have to take
an action on faulty hardware or
use the Advanced Management
Module to correct the system
configuration
Verify that loaded file was indeed
the right executable intended to
boot this system. If not, using the
Advanced Management Module
correct the system configuration.
Otherwise, contact your IBM
service representative. You may
need to add more memory to the
system or to perform the firmware
upgrade.
Contact your IBM service
representative. You may need to
perform the firmware upgrade.
Use Advanced Management
Module Web browser to specify at
least one device that contains
bootable code.
From the Advanced Management
Module Web interface, choose
BladeTasks>Configuration>Boot
Sequence.
Chapter 5. Diagnostics and troubleshooting