IBM QS21 - BladeCenter - 0792 Service Manual page 73

Problem determination and service guide
Hide thumbs Also See for QS21 - BladeCenter - 0792:
Table of Contents

Advertisement

Table 4. System board LEDs
LED
Color
Status LEDs
Heartbeat
Green
Alert
Yellow
Ethernet 1 activity
Green
Ethernet 0 activity
Green
BE0_PLL_LOCK
Green
BE1_PLL_LOCK
Green
MM_SELECT_A
Green
MM_SELECT_B
Green
Light path LEDs
DIMM at JDIM11
Yellow
error
DIMM at JDIM10
Yellow
error
DIMM at JDIM01
Yellow
error
DIMM at JDIM00
Yellow
error
Light box LEDs
Board
location Explanation
D16
Indicates the BMC is functional.
D15
Indicates an error condition has
occurred on the system board.
D12
Indicates Ethernet 1 is active and
sending or receiving packets.
D11
Indicates Ethernet 0 is active and
sending or receiving packets.
D8
Indicates the phased lock loop of
Cell/B.E.-0 is working.
D13
Indicates the phased lock loop of
Cell/B.E.-1 is working.
D19
Indicates Advanced Management
Module A is active.
D18
Indicates Advanced Management
Module B is active.
D21
There has been a failure in the
I/O DIMM module.
D20
See Figure 26 on page 54 for the
location of each DIMM and its
associated LED.
D10
D7
Comments
The status LEDs are listed for
reasons of completeness since
they are for use by IBM service
only and are not normally visible.
They are not activated by the light
path diagnostics switch.
Either remove or replace the
DIMM and reboot.
Chapter 5. Diagnostics and troubleshooting
55