Table 7. BMC test results (continued)
Test
Number
Status
166-813-
Abort
xxx BMC
166-814-
Abort
xxx BMC
166-814-
Abort
xxx BMC
166-816-
Abort
xxx BMC
166-817-
Abort
xxx BMC
166-818-
Abort
xxx BMC
Extended
results
Actions
BMC I2C test
canceled: cannot
return the
number of
requested data
bytes.
BMC I2C test
canceled:
requested
sensor, data, or
record is not
present.
BMC I2C test
1. Turn off the system and disconnect it from power. The
canceled: invalid
system must be removed from AC power in order to reset
data field in the
the BMC.
request.
2. After 45 seconds, reconnect the system to power and turn
on the system.
3. Run the test again.
4. Make sure that the DSA Diagnostic code is at the latest
level. The latest level DSA Diagnostic code can be found
on the IBM Support Web site at http://www.ibm.com/
support/docview.wss?uid=psg1SERV-DSA/.
5. Check BMC firmware level and upgrade if necessary. The
installed firmware level can be found in the DSA Diagnostic
Event Log within the Firmware/VPD section for this
component. The latest level firmware for this component
can be found on the IBM Support Web site at
http://www.ibm.com/support/us/en/.
6. Run the test again.
7. If the test continues to fail, refer to the other sections of this
chapter for diagnosis and corrective action.
BMC I2C test
canceled: the
command is
illegal for the
specified sensor
or record type
BMC I2C test
canceled: a
command
response could
not be provided
BMC I2C test
canceled: cannot
execute a
duplicated
request.