IBM QS21 - BladeCenter - 0792 Service Manual page 108

Problem determination and service guide
Hide thumbs Also See for QS21 - BladeCenter - 0792:
Table of Contents

Advertisement

Table 20. BMC firmware messages
Event
Temperature Events
Acoustic mode
Cell/B.E. processor 0 Temp
above Warning Temperature
(>73 °C)
Standard mode
Cell/B.E. processor 0 Temp
above Warning Temperature
(>82 °C)
Acoustic mode
Cell/B.E. processor 1 Temp
above Warning Temperature
(>73 °C)
Standard mode
Cell/B.E. processor 1 Temp
above Warning Temperature
(>82 °C)
Performance modeCell/B.E.
processor 0 Temp above
Warning Temperature (>80 °C)
Performance modeCell/B.E.
processor 1 Temp above
Warning Temperature (>80 °C)
90
BladeCenter QS21 Type 0792: Problem Determination and Service Guide
Severity
Message
Information Blade throttled.
Information Blade throttled.
Warning
Processor 1 (BE0
Temp) over
recommended
temperature.
Warning
Processor 2 (BE1
Temp) over
recommended
temperature.
Automatic Action by
BMC
Throttle (Reduce
Frequency).
This is a BladeCenter unit
operation which reduces
processor speed on the
blade server concerned
until the temperature has
dropped to normal levels.
Throttle (Reduce
Frequency).
This is a BladeCenter unit
operation which reduces
processor speed on the
blade server concerned
until the temperature has
dropped to normal levels.
Advanced Management
Module increases blower
speed.
Advanced Management
Module increases blower
speed.
Action required by
user
No action required.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bladecenter qs21 type 0792

Table of Contents