Table 6. BMC test results (continued)
Test
Number
Status
166-904-
Fail
xxx
166-905-
Fail
xxx
166-906-
Fail
xxx
166-907-
Fail
xxx
166-908-
Fail
xxx
166-910-
Fail
xxx
Extended
results
Actions
The BMC
1. Turn off the system and disconnect it from power. The
indicates a
system must be removed from AC power in order to reset
failure in the
the BMC.
main bus.
2. After 45 seconds, reconnect the system to power and turn
The BMC
on the system.
indicates a
3. Run the test again.
failure in the
4. Make sure that the DSA Diagnostic code is at the latest
pecos bus.
level. The latest level DSA Diagnostic code can be found
The BMC
on the IBM Support Web site at http://www.ibm.com/
indicates a
support/docview.wss?uid=psg1SERV-DSA/.
failure in the
5. Check BMC firmware level and upgrade if necessary. The
BMC private
installed firmware level can be found in the DSA Diagnostic
bus.
Event Log within the Firmware/VPD section for this
The BMC
component. The latest level firmware for this component
indicates a
can be found on the IBM Support Web site at
failure in the
http://www.ibm.com/support/us/en/.
power backplane
6. Run the test again.
bus.
7. If the test continues to fail, refer to the other sections of
The BMC
this chapter for diagnosis and corrective action.
indicates a
failure in the
microprocessor
bus.
The BMC
indicates a
failure in the
PCIe and Light
path diagnostics
bus.
Chapter 5. Diagnostics and troubleshooting
67