Blade Server Ethernet Controller Enumeration - IBM QS21 - BladeCenter - 0792 Service Manual

Problem determination and service guide
Hide thumbs Also See for QS21 - BladeCenter - 0792:
Table of Contents

Advertisement

Blade server Ethernet controller enumeration

The enumeration of the Ethernet controller or controller ports in a blade server is
operating system dependent. You can verify the Ethernet controller or controller port
designations that a blade server uses through your operating system settings.
The routing of an Ethernet controller or controller port to a particular BladeCenter
unit I/O bay depends on the type of Ethernet expansion card that is installed. You
can verify which Ethernet-controller port in this blade server is routed to which I/O
bay by using the following test:
1. Install only one Ethernet switch module or pass-thru module, in I/O bay 1.
2. Make sure that the ports on the switch module or pass-thru module are enabled
3. Enable only one of the Ethernet-controller ports on the blade server. Note the
4. Ping an external computer on the network connected to the Ethernet switch
Communications from optional I/O expansion cards are routed to I/O bays 3 and 4.
If you have installed an I/O expansion card on the blade server you can verify
which controller port on an expansion card is routed to which I/O bay by performing
the same test, using a controller on the expansion card and a compatible switch
module or pass-thru module in I/O bay 3 or 4.
26
BladeCenter QS21 Type 0792: Problem Determination and Service Guide
(Switch Tasks → Management → Advanced Switch Management in the
BladeCenter Management Module Web interface).
designation that the blade server operating system has for the controller port.
module. If you can ping the external computer, the Ethernet-controller port that
you enabled is associated with the switch module in I/O bay 1. The other
Ethernet-controller port in the blade server is associated with the switch module
in I/O bay 2.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bladecenter qs21 type 0792

Table of Contents