Porsche 928 Workshop Manual page 231

Hide thumbs Also See for 928:
Table of Contents

Advertisement

928
Differential.
Transaxle
Svstem
39
Procedure
Execution
I Notes
Example:
Measurement
2 = Gauge pressure
lo...20 bar
Actual values: Gauge pressure = 13 bar,
locking torque measured = 240 Nm (177 ftlb)
Specified value according
to table at 13 bar:
120...300
Nm (88...221 ftlb)
Measurement
2 o.k. since results are within the
tolerance band (boundary
value window)
- Measurement
4 = Minimum
locking
torque of
500 Nm (369 ftlb) must be
ensured.
Equivalent
pressure
60 bar or higher
- Measurement
5 = pilot pressure
valve
Proceed to pressure release position and read off
pressure at gauge. Specified value: approx.
3.0...4.5 bar. If measurements
are out of limits,
repeat process, starting from low pressure
max.
20 bar. In this case, release pressure by switching
off ignition.
a
PSD-Diagnosis
/ Troubleshooting
D39- 211
Printed in Germany . XXVII, 1991