McDATA StorageWorks 64 - SAN Director Switch Manual page 165

E/os snmp
Hide thumbs Also See for StorageWorks 64 - SAN Director Switch:
Table of Contents

Advertisement

fcConnUnitDeletedTrap
Type Number
Product Mapping
OID and Value
Description
fcConnUnitEventTrap
Type Number
Product Mapping
OID and Value
Description
fcConnUnitSensorStatusChange
Type Number
Product Mapping
OID and Value
Description
fcConnUnitPortStatusChange
Type Number
Product Mapping
2
Not supported on the connUnit.
N/A
An fcConnUnit has been deleted from this agent. Recommended
severity level (for filtering): warning.
3
Generated when a new event is generated.
".1.3.6.1.2.1.8888.1.1.7.1.1" + unitId
fcConnUnitEventIndex,
".1.3.6.1.2.1.8888.1.1.7.1.5" + unitId
".1.3.6.1.2.1.8888.1.1.7.1.6" + unitId
fcConnUnitEventObject
".1.3.6.1.2.1.8888.1.1.7.1.7" + unitId
fcConnUnitEventDescr
An event has been generated by the connectivity unit.
Recommended severity level (for filtering): info.
4
Generated when one of the fans or power supply status is changed.
".1.3.6.1.2.1.8888.1.1.5.1.3" + unitId + sensor_nbr
fcConnUnitSensorState
The overall status of the connectivity unit has changed.
Recommended severity level (for filtering): alert.
5
Generated when a port state or status is changed.
fcConnUnitEventType
,