McDATA StorageWorks 64 - SAN Director Switch Manual page 123

E/os snmp
Hide thumbs Also See for StorageWorks 64 - SAN Director Switch:
Table of Contents

Advertisement

FcConnUnitContact
Type
Product Mapping
Access
Description
FcConnUnitLocation
Type
Product Mapping
Access
Description
FcConnUnitEventFilter
Type
Access
NOTE: Each implementation may chose not to support SNMP Set operations
for any or all of these values. For Sets specifying varbinds for instances of this
object and values not supported by a given implementation, the agent will
return the SNMP WrongValue PDU error code.
The values are defined as follow: unknown (1), invalid (2),
resetConnUnitColdStart (3), resetConnUnitWarmStart (4),
offlineConnUnit (5), onlineConnUnit (6).
SnmpAdminString
Contact information for this connectivity unit.
Writable and persistent across IPL.
R/W
Contact information for this connectivity unit. The contact
information is intended to facilitate contacting someone in case of
problems, questions, etc. (e.g., the help desk internal to a company).
SnmpAdminString
The physical location of the switch.
Writable and persistent across IPL.
R/W
Location information for this connectivity unit.
FcEventSeverity
Writable and it's set to the Default value of info(8) after IPL.
R/W
This value defines the event severity that will be logged by this
connectivity unit. All events of severity less than or equal to
fcConnUnitEventFilter
are logged in the
fcConnUnitEventTable
Fibre Alliance MIB
McDATA SNMP Support
.
2-105