Table 76 SNMP Traps (continued)
TRAP NAME
reboot
overheat
overheatOver
voltageOutOfRange
voltageNormal
thermalSensorFailure
sysMacAntiSpoofing
222
DESCRIPTION
Send a message to the manager that the system
is going to reboot. The variable is the reason why
the system reboots.
Send a message to the manager that the system
is overheated. The variable in the binding list is
the current temperature in Celsius of the system.
Send a message to the manager that the
overheated condition is over. The variable in the
binding list is the current temperature in Celsius
of the system.
Send a message to the manager that the voltage
of the system is out of range. The variable in the
binding list is the current voltage in volt of the
system.
Send a message to the manager that the low-
voltage condition is over. The variable in the
binding list is the current voltage in volt of the
system.
The trap signifies that the thermal sensor failed.
MAC Anti-spoofing.
OID
STU-C:
1.3.6.1.4.1.890.1.5.5.7.1
STU-R:
1.3.6.1.4.1.890.1.5.5.8.1
STU-C:
1.3.6.1.4.1.890.1.5.5.7.3
STU-R:
1.3.6.1.4.1.890.1.5.5.8.3
STU-C:
1.3.6.1.4.1.890.1.5.5.7.4
STU-R:
1.3.6.1.4.1.890.1.5.5.8.4
STU-C:
1.3.6.1.4.1.890.1.5.5.7.8
STU-R:
1.3.6.1.4.1.890.1.5.5.8.8
STU-C:
1.3.6.1.4.1.890.1.5.5.7.9
STU-R:
1.3.6.1.4.1.890.1.5.5.8.9
STU-C:
1.3.6.1.4.1.890.1.5.5.7.22
STU-R:
1.3.6.1.4.1.890.1.5.5.8.22
STU-C:
1.3.6.1.4.1.890.1.5.5.7.12.1.1
1
STU-R:
1.3.6.1.4.1.890.1.5.5.8.12.1.1
1
IES-708-22A User's Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ies-708Ies-708-22a

Table of Contents