ZyXEL Communications IES-22A User Manual page 199

8-port g.bis mini-dslam
Table of Contents

Advertisement

Table 64 Advanced Application > PPPoA to PPPoE (continued)
LABEL
AC Name
Service Name
Hellotime
Apply
Cancel
Show Port
Index
Port
VPI/VCI
PVID
Priority
Hellotime
DS / US VC Profile
Access
Concentrator Name
Service Name
Select
Delete
Select All
Select None
IES-708-22A User's Guide
DESCRIPTION
This field is optional. Specify the hostname of a remote access concentrator if
there are two access concentrators (or BRAS) on the network or if you want to
allow PAE translation to the specified access concentrator. In this case, the IES-
708-22A checks the AC name field in the BRAS's reply PDU. If there is a
mismatch, the IES-708-22A drops this PDU. (This is not recorded as an PPPoE
AC System Error in the PPPoA to PPPoE Status screen, however.)
This field is optional. Specify the name of the service that uses this PVC. This
must be a service name that you configure on the remote access concentrator.
Specify the timeout, in seconds, for the PPPoE session. Enter 0 if there is no
timeout.
Click this to add or save channel settings on the selected port.
This saves your changes to the IES-708-22A's volatile memory. The IES-708-
22A loses these changes if it is turned off or loses power, so use the Config
Save link on the navigation panel to save your changes to the non-volatile
memory when you are done configuring.
Click Cancel to start configuring the screen again.
Select which DSL port(s) for which to display PPPoA to PPPoE conversion
settings.
This field displays the number of the PVC. Click a PVC's index number to open
the screen where you can look at the current status of this PPPoA-to-PPPoE
conversion. (See
Section 29.3 on page
Note: At the time of writing, you cannot edit the VPI and VCI. If
you want to change them, add a new PVC with the desired
settings. Then, delete any unwanted PVCs.
This field displays the number of the DSL port on which the PVC is configured.
This field displays the Virtual Path Identifier (VPI) and Virtual Circuit Identifier
(VCI). The VPI and VCI identify a channel on this port.
This is the PVID (Port VLAN ID) assigned to untagged frames or priority frames
(0 VID) received on this channel.
This is the priority value (0 to 7) added to incoming frames without a (IEEE
802.1p) priority tag.
This field displays the timeout for the PPPoE session, in seconds.
This shows which VC profile this channel uses for downstream traffic shaping.
The VC profile for upstream policing also displays if the channel is configured to
use one.
This field displays the name of the specified remote access concentrator, if any.
This field displays the name of the service that uses this PVC on the remote
access concentrator.
Select the check box in the Select column for an entry, and click Delete to
remove the entry.
Click this to select all entries in the table.
Click this to un-select all entries in the table.
Chapter 29 PPPoA to PPPoE
200.)
199

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ies-708Ies-708-22a

Table of Contents