Show Env - Cisco WS-C2350-48TD-S Command Reference Manual

Command reference
Table of Contents

Advertisement

show env

show env
Use the show env user EXEC command to display fan, temperature, and power information for the
switch.
Syntax Description
all
fan
power
temperature
temperature
status
| begin
| exclude
| include
expression
Command Modes
User EXEC
Command History
Release
12.2(46)EY
Usage Guidelines
Use the show env user EXEC command to display the information for the switch.
If you enter the show env temperature status command, the command output shows the switch
temperature state and the threshold level.
You can also use the show env temperature command to display the switch temperature status. The
command output shows the green and yellow states as OK and the red state as FAULTY. If you enter the
show env all command, the command output is the same as the show env temperature status command
output.
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output
are not displayed, but the lines that contain Output are displayed.
Examples
This is an example of output from the show env all command on a switch:
Switch> show env all
FAN is OK
TEMPERATURE is OK
Temperature Value: 42 Degree Celsius
Temperature State: GREEN
Yellow Threshold : 49 Degree Celsius
Red Threshold
Catalyst 2350 Switch Command Reference
2-260
show env {all | fan | power | temperature [status]} [ | {begin | exclude | include} expression]
Display the fan and temperature environmental status and the status of the internal
power supply.
Display the switch fan status.
Display the switch internal power status.
Display the switch temperature status.
(Optional) Display the switch internal temperature (not the external temperature)
and the threshold values.
(Optional) Display begins with the line that matches the expression.
(Optional) Display excludes lines that match the expression.
(Optional) Display includes lines that match the specified expression.
Expression in the output to use as a reference point.
Modification
This command was introduced.
: 69 Degree Celsius
Chapter 2 Catalyst 2350 Cisco IOS Commands
OL-19055-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 2350

Table of Contents