Cisco WS-C2350-48TD-S Command Reference Manual page 76

Command reference
Table of Contents

Advertisement

diagnostic monitor
Command History
Release
12.2(46)EY
Usage Guidelines
Follow these guidelines when configuring health-monitoring diagnostic testing:
You must configure the failure threshold and the interval between tests before enabling diagnostic
monitoring.
When entering the diagnostic monitor switch number test {name | test-id | test-id-range | all}
command, you must isolate network traffic by disabling all connected ports, and do not send test packets
during the test.
Examples
This example shows how to configure a health-monitoring test:
Switch(config)# diagnostic monitor threshold switch 2 test 1 failure count 20
Switch(config)# diagnostic monitor interval switch 2 test 1 12:30:00 750 5
Related Commands
Command
show diagnostic
Catalyst 2350 Switch Command Reference
2-52
Modification
This command was introduced.
name—Enter the
show diagnostic
the test ID list.
test-id—Enter the
show diagnostic
test-id-range—Enter the
show diagnostic
ID list. Enter the range as integers separated by a comma and a hyphen (for example, 1,3-6 specifies
test IDs 1, 3, 4, 5, and 6).
hh—Enter the hours from 0 to 24.
mm—Enter the minutes from 0 to 60.
ss—Enter the seconds from 0 to 60.
milliseconds—Enter the test time in milliseconds from 0 to 999.
day—Enter the number of days between test from 0 to 20.
Enter the diagnostic monitor test 1 command to enable diagnostic monitoring.
content privileged EXEC command to display the test names in
content command to display the test numbers in the test ID list.
content command to display the test numbers in the test
Description
Displays online diagnostic test results.