Using Hold Functions

The hold functions hold data for specific points during the measurement period (sampling
period), such as the maximum or minimum value, and output those values at the end of the
measurement period.
The value that will be held during the sampling period is selected here.
Current measured value
Measurement starts*
The CLAMP value is output until the first sampling period is finished.
CLAMP value, p. 88
Selection
OFF (default)
P-H (Peak hold)
B-H (Bottom hold)
Hold condition (which value to hold)
Sampling period
Measurement ends*
* The timing input method depends on the hold conditions.
Hold measurement is not performed. The current measured value is always out-
put.
Holds the maximum value during the sampling period. The sampling period is
the period that the timing signal is ON.
ON
Timing input
OFF
Holds the minimum value during the sampling period. The sampling period is the
period that the timing signal is ON.
ON
Timing input
OFF
DETAILED SETTINGS
Output
Value is held until the next time the
hold condition is met.
Details
Maximum
value
Sampling period
Minimum
value
Sampling period
Section 5
Output
Output
ZX-T
71
Operation Manual